RI 7998 - Noise Abatement Of Pneumatic Rock Drill

The National Institute for Occupational Safety and Health (NIOSH)
C. R. Summers J. N. Murphy
Organization:
The National Institute for Occupational Safety and Health (NIOSH)
Pages:
51
File Size:
5977 KB
Publication Date:
Jan 1, 1974

Abstract

In response to the Coal Mine Health and Safety Act of 1969, mandatory noise standards have been developed that specify time-noise limits of mine personnel exposure. Most affected by elevated noise levels is the pneumatic roof bolter operator, both in terms of levels near or in excess of 115 dbA and in terms of length of exposure. Therefore, the principal emphasis of this Bureau of Mines report is on pneumatic drill noise control. It is not the intent of this report to suggest any drill redesign; instead, methods are suggested to reduce the noise level by complementing existing machines. An integral muffler system and a separate muffler system were tested in an attempt to lower pneurnaric drill noise levels. Pneumatic drills, when new, operate at about 115 dbA when drilling in sandstone. Using the drill muffler systems, it was possible to decrease the noise level of a 115 -dbA s rope drill to approximately 100 dbA.
Citation

APA: C. R. Summers J. N. Murphy  (1974)  RI 7998 - Noise Abatement Of Pneumatic Rock Drill

MLA: C. R. Summers J. N. Murphy RI 7998 - Noise Abatement Of Pneumatic Rock Drill. The National Institute for Occupational Safety and Health (NIOSH), 1974.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account