The electrification of ammonium nitrate-fuel oil (AN-FO) blasting agents by pneumatic loaders is described and discussed. The consequences of the electrification are considered in light of the initiation requirements of electric blasting caps. It is recommended (1) that semiconductive loading tubing be utilized and (2) that the resistivity of the AN-FO be controlled; it is further recommended that the operator (3) test to assure continuity of the electric detonator legwire-bridgewire-legwire circuit prior to insertion of the cap into charge or borehole, (4) keep the legwires shunted but not otherwise connected to ground during loading of the blasting agent into the borehole, (5) assure that the borehole is discharged prior to hooking up the detonator leads, (6) assure that he is himself discharged prior to handling the detonator leads, and (7) assure that the blasting cap leads are never carried to the AN-FO loader. The basis and significance of these recommendations are explained.