RI 6269 Use Of Calcined Anthracite In Foundry Cupolas

- Organization:
- The National Institute for Occupational Safety and Health (NIOSH)
- Pages:
- 17
- File Size:
- 2645 KB
- Publication Date:
- Jan 1, 1963
Abstract
Tests were conducted in commercial foundries to determine the suitability of calcined anthracite as a cupola fuel. The calcined anthracite performed satisfactorily at two of the three foundries where iron-melting tests were conducted. Performance at the third installation was unsatisfactory because metal temperatures deviated widely and, in general, were lower than is desirable for the type of castings being made.
Citation
APA: