An ethanolamine purification unit for removing carbon dioxide and hydrogen sulfide from Firscher-Tropsch synthesis gas was installed at the Bureau of Mines synthetic liquid fuels demonstration plant at Louisiana, Mo. The unit was a surplus Radford Girbotol unit from the Missouri Ordnance Works modified for a capacity of 90,000 std. cu. ft per hour of synthesis gas at 450 p.s.i.g., operating pressure. The hydrogen sulfide loading of the feed gas was specified at 500 grains per 100 cu. Ft. The unit was designed by the Girdler Corp. and installed by the Koppers Co. Initial operations were conducted far 11 days in May 1951. Thereafter 7 additional runs were made, varying lo duration from 8 to 54 days. The last run was terminated on May 29, 1953, the total time the Plant wars in operation being 219 days.