Reservoir Engineering – Laboratory Research - Evidence of Chromatographic Effect During Flow of Gases Through Oilfield Cores

The American Institute of Mining, Metallurgical, and Petroleum Engineers
W. A. Roper
Organization:
The American Institute of Mining, Metallurgical, and Petroleum Engineers
Pages:
3
File Size:
885 KB
Publication Date:

Abstract

Since 1950, several papers have been published which have described various methods for studying mobility ratio effects. The methods which have been described for studying mobility ratio effects include X-ray shadowgraph techniques, stepwise potentiometric model procedures, stepwise numerical procedures, gelatin model studies and fluid mapper model studies. The purpose of this paper is to describe a procedure for using a resistance network for studying mobility effects. DESCRIPTION OF APPARATUS The basic unit of the experimental model consisted of a network of 840 resistors fastened to a sheet of black Lucite which was mounted on a wooden frame, Fig. 1. The dimensions of the Lucite sheet were 36 X 36 in. The resistors were fastened to the Lucite sheet at mesh points by means of snaps. The mesh points were arranged in a square pattern, 30 X 30 in., spaced at intervals of l1/2 in. The snap fasteners permitted several resistors to be "stacked" in parallel. By adding additional resistors to the basic unit, the specific resistance on each side of the flood front could be varied. The square network of resistors represented one of four symmetrical elements of a five-spot well pattern. The current input was analogous to an injection well and the current output was analogous to a production well." The power supply was essentially a full wave transformer-rectifier system for converting alternating-current into direct-current. The DC voltage could be varied from 41.43 to 290 v in steps of 41.43 v by selecting the proper outlet jacks. The major components of the power supply were: a Triro power transformer, R 11-A; a dual 5Y3 vacuum tube; two gas filled OD-3 tubes; and a Triplett voltmeter, model 227-1, range 0 to 500 DC v. The voltages at the mesh points were determined with a Keithley electrometer, model 210, No. 185, manufactured by Keithley Instruments, Cleveland, Ohio. A Heathkit vacuum tube volt-
Citation

APA: W. A. Roper  Reservoir Engineering – Laboratory Research - Evidence of Chromatographic Effect During Flow of Gases Through Oilfield Cores

MLA: W. A. Roper Reservoir Engineering – Laboratory Research - Evidence of Chromatographic Effect During Flow of Gases Through Oilfield Cores. The American Institute of Mining, Metallurgical, and Petroleum Engineers,

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account