Progress of "Big Blasting" at Climax

- Organization:
- The American Institute of Mining, Metallurgical, and Petroleum Engineers
- Pages:
- 13
- File Size:
- 454 KB
- Publication Date:
- Jan 1, 1938
Abstract
IN the first big blast at Climax, a "loop back" (three-wire system) was used (Fig. 1), with the idea of securing a wiring system that would give to all series the same amount of current. Single-phase, 60-cycle, 13,800-volt FIG. 1.-Loop BACK. A THREE-WIRE SYSTEM WITH BRANCHES VARYING IN LENGTH. power was furnished to the blasting transformers, each of which has a rated capacity of 600 amp. at 480 volts. Two blasting leads were taken from these transformers, giving a blasting current of single phase, 60 cycle, 480 volts, with an instantaneous capacity of more than 600 amp. The blasting switch was on the secondary leads from the transformers, to avoid lag in energizing them.