Federal mine safety regulations prohibit the recirculation of face air In a gassy Class III metal-non metal mine. Tg Soda Ash, Inc, operates a 2.0M ton/yr (2.2 million st/yr) underground gassy Class III trona mine In southwest Wyoming, currently liberating approximately 5,700 m3/day (200,000 ft3/day) of methane. Because of the low methane emissions and the incombustibllity of trona, it was decided that Tg would be an excellent environment to test recirculation at a U. S. gassy mine, for possible future use by Industry. A research program was begun with the cooperation of MSHA, the U.S. Bureau of Mines, the University of Utah, and Tg. Initial testing centered around re-using shop air under¬ground. Next, conduct a continuous miner section recirculation test to see how the face contamination was affected by 305m (1,000 ft) and 610m (2,000 ft) recirculation distances. A district test followed to examine the effects of the critical parameter - respirable dust. Finally, a long-term program to study respirable trona dust transportation and deposition in mine airways to plan for district fan siting and effects on face air dust levels.
Citation
APA:
(1995) Preparatory Work Required for a Long-Term District Recirculation Test in a Gassy Underground Metal-Non Metal MineMLA: Preparatory Work Required for a Long-Term District Recirculation Test in a Gassy Underground Metal-Non Metal Mine. Society for Mining, Metallurgy & Exploration, 1995.