Pile Design According to Eurocode 7, Highlights and Developments

Deep Foundations Institute
Adriaan van Seters
Organization:
Deep Foundations Institute
Pages:
4
File Size:
141 KB
Publication Date:
Jan 1, 2014

Abstract

"Abstract The content of Eurocode 7 – Part 1 and Part 2 – with respect to piled foundations is outlined. The important role of pile testing is presented and the derivation of the characteristic value of pile bearing resistance is explained. Recommendations for the use of correlation factors are given. The ongoing work of the Evolution Groups on piling is to prepare a revision of Eurocode 7 after 2019. Future topics and changes are highlighted.General outline of pile design by Eurocode 7In his paper for this conference Frank (2014) outlined the various aspects of standardisation for pile foundations, which involves Eurocode 7 as leading for pile construction in Europe. Standards for pile testing and execution of piling works were established in the last 15 years.This paper focuses on the design of piled foundations according to the design code Eurocode 7, which consists of 2 parts:EN 1997-1 Geotechnical design - Part 1: General Rules (CEN, 2004);EN 1997-2 Geotechnical design – Part 2: Ground investigation and testing (CEN, 2007) In Eurocode 7-1, Section 7 – Pile Foundations - deals with the design of piles. The safety concept for pile design is given in Section 2 – Basis of Geotechnical Design - for the three Design Approaches.In Section 7 presents the design of piles according to four methods:1. Results of static load tests2. Empirical or analytical calculation methods3. Results of dynamic load tests4. Observed performance of a comparable pile foundation.Guidelines for the ground investigation for piles is provided in Eurocode 7-2, Annex B.3. In the Annexes of Eurocode 7-2 examples of analytical methods to determine the bearing resistance of a single pile based on the results of various ground investigation techniques are given. Thus calculation models are presented based on design using the results of Cone Penetration Tests (D.6 and D.7) and Pressuremeter Tests (E.3). The Annexes of Eurocode 7-2 are informative.For the interpretation of Eurocode 7, reference is made to Frank et al (2004) and Bond and Harris(2008)."
Citation

APA: Adriaan van Seters  (2014)  Pile Design According to Eurocode 7, Highlights and Developments

MLA: Adriaan van Seters Pile Design According to Eurocode 7, Highlights and Developments. Deep Foundations Institute, 2014.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account