ATLAS Processing Company Shrevesport, LA initiated a major plant expansion in 1980. SITE Engineers, Inc. provided engineering consultation regarding the foundation of the vacuum unit. Four test borings were drilled and laboratory testing completed for shear strength and compressibility. Vertical drains were proposed to accelerate time rates of settlements. Steel erection was completed by May 22, 1981 with very small < 0.1 in., settlements. Hydrotesting was initiated on July 9, 1981 and completed on August 27, 1981. An average rebound of 0.3 in. was computed resulting into an average net settlement of 0.5 in. This paper describes in detail soil behavior during load testing.