Type 1B micropiles (Bruce and Juran, 1997) can be installed rapidly and efficiently. During an 85-day period, 536 micropiles were installed to depths of 61 meters within a site 41 meters by 43 meters. Their performance, as measured by load test, varied even where the materials, construction procedure, and installation technique were closely monitored and controlled. The variation in displacement, as measured by the standard deviation, exceeded 50 percent of the mean test-load displacement for all loads up to the maximum load applied (2670 kN). This study provides a statistical basis to predict variability with respect to the construction method, micropile materials, and installation technique. The variability of displacement at all test loads is a fundamental characteristic of this type of drilled deep foundation system.