Method Of Testing Draeger Oxygen Helmets At The Copper Method Of Testing Draeger Oxygen Helmets At The Copper Queen Mine.

The American Institute of Mining, Metallurgical, and Petroleum Engineers
C. A. Mitke
Organization:
The American Institute of Mining, Metallurgical, and Petroleum Engineers
Pages:
4
File Size:
495 KB
Publication Date:
Jan 7, 1913

Abstract

(Butte Meeting, August, 1913.) 1. Character of Gases which Caused Helmets to Get Out of Order. DURING September, -1911, the fire area in the Lowell mine continually increased and gases resulting from the fire came through the upcast shaft. These gases contained such a large percentage of sulphur dioxide that the men were unable to go up and down on cages, and, within a comparatively short time, repairs in the shaft were found to be necessary. Since the fire was in sulphide ores and extended into certain timbered sections, the gases contained varying amounts of SO2 CO2, and perhaps, at times, CO. The temperature in the shaft was generally about 97°, and the relative humidity from 97 to 99.5 per cent. The corrosive action of the fumes became apparent when the cables had to be changed more often than usual, the heads of lag screws .in the guides of the shaft disappeared, and the cages needed frequent repairs. It also became necessary to repair two compartments of the shaft by putting in 150 ft. of new guides between the 600 and 800 levels and lag screws in nearly all the old guides from the surface to the 800 level. 2. Ordinary Methods of Testing Helmets which were Unsatisfactory. These conditions required all work to be done by men wearing oxygen helmets. The Draeger type was tried, and was used until all repairs were completed. At first the helmets were. tested for air circulation and air tightness and the injector was tested by water gauge according to the methods recommended by the Draeger Oxygen Apparatus Co. Six arrangements, covering .these different tests, are illustrated in the catalogue and circulars of the company.
Citation

APA: C. A. Mitke  (1913)  Method Of Testing Draeger Oxygen Helmets At The Copper Method Of Testing Draeger Oxygen Helmets At The Copper Queen Mine.

MLA: C. A. Mitke Method Of Testing Draeger Oxygen Helmets At The Copper Method Of Testing Draeger Oxygen Helmets At The Copper Queen Mine.. The American Institute of Mining, Metallurgical, and Petroleum Engineers, 1913.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account