Leach Residue Filtration at the Hudbay Zinc Pressure Leach Plant

- Organization:
- Canadian Institute of Mining, Metallurgy and Petroleum
- Pages:
- 7
- File Size:
- 263 KB
- Publication Date:
- Jan 1, 2012
Abstract
"After cooling and thickening, slurry from the second stage of the Hudbay zinc pressure leach circuit is filtered and washed on a belt filter prior to disposal. At times, the belt filter can be a bottleneck to the process. Preliminary studies show that filterability of the second-stage (HAL) autoclave leach residue can be indicated by particle size distribution of the filter feed and filtered residue cake. In particular, the Volume Weighted Mean Diameter, D[4,3], generated by a laser diffraction particle size analyzer from samples of HAL Filter feed, shows residues that filter more poorly have a lower Volume Weighted Mean Diameter than those that filter better. INTRODUCTIONHudbay produces cast zinc metal from blends of zinc concentrates at its metallurgical complex in Flin Flon, Manitoba, Canada, using Sherritt’s two-stage pressure leach process (Collins et al., 1994; Collins et al., 1995; Barth et al., 1998; Shairp et al., 2006). Pressure leaching replaced the original roastleach- electrowinning process in 1993.Filtration for the second-stage (HAL) leach residue originally consisted of two stages of vacuum drum filtration with intermediate cake repulping stirred tanks. As part of Hudbay’s 777 Project, with a designed increase in cast zinc production, a pre-feasibility study by SNC-Lavalin Inc. showed that losses of soluble zinc in the zinc pressure leach residue could be reduced by installing more efficient filtering and washing equipment. Based on laboratory performance, capital cost, installation ability, and potential operating cost savings, a 70 m2 Filtres Phillipe belt filter was chosen for the HAL residue, and commissioned in 2000/2001.When the HAL belt filter is performing well, there is no pooling of water on the surface, moisture content is relatively low, and subsequent analysis shows that water soluble zinc content is relatively low. There have been occasions where the filter has performed poorly with respect to the aforementioned parameters. Aside from the filter experiencing mechanical difficulties, there are several variables affecting leach residue filtration:"
Citation
APA:
(2012) Leach Residue Filtration at the Hudbay Zinc Pressure Leach PlantMLA: Leach Residue Filtration at the Hudbay Zinc Pressure Leach Plant. Canadian Institute of Mining, Metallurgy and Petroleum, 2012.