"The Taguchi method was used as the experimental design to determine the optimum conditions of cementation behavior of the ruthenium chloride solution. Cementation was carried out using metallic zinc powder. The experimental conditions were studied in the range of 25-45°C for reaction temperature (A), 30--60 min for reaction time (B), 0.5-1.5 for pH of solution (C), and 30--50 mg for zinc powder (D). Experimental parameters and their levels were determined in the light of preliminary tests. Orthogonal array (OA) L9(34) consisting of four parameters each with three levels, was chosen. The optimal conditions found for ruthenium, such as a reaction temperature, reaction time, pH of the solution and mass of zinc, are respectively: 45°C, 45 min, 1.5 and 50 mg. Under these conditions, the ruthenium cementation efficiency obtained by theoretically and experimentally was in good agreement, which were 99.8% and 99.7% respectively."