Institute of Metals Division - Dislocation Blocking in Face-Centered-Cubic Metals

The American Institute of Mining, Metallurgical, and Petroleum Engineers
I. R. Kramer
Organization:
The American Institute of Mining, Metallurgical, and Petroleum Engineers
Pages:
5
File Size:
1439 KB
Publication Date:
Jan 1, 1960

Abstract

A delay time for yielding in cold-worked face-centered-cubic metals was found. Slip on (123) planes was observed. Glide on these planes occurred during the delay-time period before slip starts on the (111) planes. AN important approach to the study of the anchoring and blocking of dislocations is available through the delayed-yield phenomenon which has been observed in body-centered and hexagonal close-packed metal by several investigators. Clark and his associate1-5 showed that a delay time for yielding is present in mild steels and fine-grain molybdenum. Type 302 stainless, SAE 4130 normalized, SAE 4130 quenched and tempered, and 24s-T aluminum aid not have a delay time. Kramer and Maddin6 studied the delay-yield effect. in metal single crystals. While they found a delay time in body-centered-cubic metals none could be found in the face-centered-cubic metals. Later7 a delay time was found in hexagonal close-packed metals. cottrell8 has proposed an explanation for the difference in the yield phenomena of b.c.c. and f.c.c. metals based upon the anchoring of edge dislocations by the proper types of impurity atoms (C and N). In the body-centered-cubic lattice the interstitial atoms are near a cube edge and can interact with an edge dislocation, while in a face-centered-cubic lattice the distortion around an interstitial atom is of spherical symmetry and cannot anchor a screw dislocation which has practically no hydrostatic component. Cottrell's theory seems to account rather well for the behavior of body-centered-cubic . metals. EXPERIMENTAL PROCEDURE The apparatus used in these experiments is essentially of the same design as described previously.' Single crystals 1 in. long and having a diameter of % in. were placed in a pendulum which consisted of a bar 8 ft long designed with a crystal holder to accommodate the specimen at low temperatures. This portion of the apparatus was supported on fine molybdenum wires. A bar of the same diameter and length comprised the other portion of the apparatus. This bar was supported on a set of roller bearings arranged around the periphery of the bar to allow accurate alignment. This bar was propelled by means of a spring-loaded gun and allowed to strike the lead bar in front of the single-crystal specimen. SR-4 type A-8 resistance strain gages were cemented to the specimen and the strain measurements were obtained by amplifying the strain-gage output by means of a high-gain preamplifier. A tektronix 545 oscilloscope was used together with a polaroid camera to record the strain and time sweep. An Ellis Associate Bridge was used to calibrate the strain gages and calibration readings were obtained before each test. The sweep of the time signal was initiated by means of a miniature thyraton which was fired when the two bars came into contact. The single-crystal specimens were cut from single-crystal bars about 12 in. long, grown by a modified Bridgman technique. The aluminum crystals were made with material of 99.99 pct purity while the purity of the copper was 99.999 pct. A cut-off wheel was used to prepare the specimens which were then machined to the desired length. The two opposite faces of the specimen were parallel to each other and perpendicular to the axis of the specimen. The specimens were compressed 1 pct. No machining followed thereafter. In some cases prestraining was carried out in liquid nitrogen by impacting the specimens directly in the apparatus so that subsequent observations could be made without allowing the specimen to warm up to room temperature. The single crystals were compressed 1 pct at room temperature in a hand press without much control of the rate of deformation. In some cases specimens were recompressed to obtain the desired length change. As far as could be determined in these experiments this factor did not seem to influence the results. The SR-4 strain gages were glued with a cellulose type cement onto the specimen surface and baked at 45°C for 12 hr. As a check on the baking treatment gages were allowed to dry at room temperature. All delay time tests in this paper were conducted in a liquid nitrogen bath at -195°C. A schematic delay time oscilloscope trace is shown in Fig. 1. At point B the elastic stress wave caused by the impact reaches the strain gage on the specimen. The portion BC is the elastic strain. In this investigation the strain at point C was used to calculate the critical resolved shear stress by multiplying by the proper modulus depending upon the orientation of the single-crystal specimen. The time between C and D is the delay time portion of the curve. This portion of the curve is fairly flat but does have a definite microstrain associated with it. After the point D is reached the specimen deforms rapidly and the strain reaches a maximum at E. Following this, depending upon the length of the bar behind the specimen, the strain remains constant for a period and then decreases when the reflected elastic wave returns from the end of the pendulum bar. A permanent plastic strain is recorded on the oscilloscope trace and also measured by a strain-measuring bridge. The strain, E p,
Citation

APA: I. R. Kramer  (1960)  Institute of Metals Division - Dislocation Blocking in Face-Centered-Cubic Metals

MLA: I. R. Kramer Institute of Metals Division - Dislocation Blocking in Face-Centered-Cubic Metals. The American Institute of Mining, Metallurgical, and Petroleum Engineers, 1960.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account