Improving Fine Particle Flotation Selectivity at Hellyer

- Organization:
- The Australasian Institute of Mining and Metallurgy
- Pages:
- 8
- File Size:
- 378 KB
- Publication Date:
- Jan 1, 1993
Abstract
The Hellyer concentrator of Aberfoyle Limited commenced production in 1989 processing a fine grained, massive sulphide ore containing Zn, Pb, Ag, Cu and Au as values. Four concentrates are produced - copper/silver, lead, zinc and bulk (Pb/Zn) - with overall payable recoveries (1991) of 80 per cent Zn, 55 per cent Pb, 50 per cent Ag, 30 per cent Cu and ten per cent Au. Metallurgical development work commenced immediately after plant commissioning, and continues. The flotation response and liberation analysis on a size basis highlighted reagent balance problems associated with tower mill regrinding of sphalerite, poor conditioning of flotation pulps, poor selectivity for fine galena, and insufficient liberation. These were the main causes of values lost to tailings, values reporting to the 'wrong' concentrates and of impurities in the concentrates. Modifications to tower mill regrind circuit operation, and the use of improved conditioning techniques have greatly improved concentrator performance, particularly in the finer (-5 micron) size fractions. Studies of concentrator and laboratory flotation by size and liberation analysis are the basis of diagnostic metallurgy. The techniques used to evaluate the improved concentrator performance are discussed.
Citation
APA:
(1993) Improving Fine Particle Flotation Selectivity at HellyerMLA: Improving Fine Particle Flotation Selectivity at Hellyer. The Australasian Institute of Mining and Metallurgy, 1993.