IC 9144 Spontaneous Combustion Fire Detection For Deep Metal Mines

The National Institute for Occupational Safety and Health (NIOSH)
William H. Pomroy
Organization:
The National Institute for Occupational Safety and Health (NIOSH)
Pages:
30
File Size:
11931 KB
Publication Date:
Jan 1, 1987

Abstract

Spontaneous combustion fires involving high-sulfide-content ores are a relatively infrequent yet serious safety hazard in mining. They are also the cause of lengthy mine shutdowns because they typically occur in areas of a mine where abundant fuel material is present but which are inaccessible for fire fighting. This Bureau of Mines report describes research to design, fabricate, and test in the laboratory and field a system that warns of spontaneous combustion fires in metal mines. Overall performance of the detection system was found to be satisfactory, in that the system was capable of reliably detecting low levels of combustion products believed to indicate the preflaming stage of spontaneous combustion in metal mines. Installation of similar systems in mines with a high risk of spontaneous combustion is recommended. Principal operating problems and recommended corrective actions are also discussed.
Citation

APA: William H. Pomroy  (1987)  IC 9144 Spontaneous Combustion Fire Detection For Deep Metal Mines

MLA: William H. Pomroy IC 9144 Spontaneous Combustion Fire Detection For Deep Metal Mines. The National Institute for Occupational Safety and Health (NIOSH), 1987.

Export
Purchase this Article for $25.00

Create a Guest account to purchase this file
- or -
Log in to your existing Guest account