A line of nine self-aspirating W emco cells, part of the Rougher circuit at Division Salvador, Codelco Chile, was retrofitted to allow operation with forced air. Each cell could be operated self-aspirated or with compressed air supplied through a 4-inch line equipped with a mass flow meter. Gas dispersion was characterized for the two modes of operation. Metallurgical performance was compared under self-aspirated conditions and with different gas profiles under forced air conditions. Cell characterization demonstrated that with forced-air the cells could not evenly distribute air across the cell volume. Bubble size increased with gas velocity, as expected, with no difference between self-aspirated and forced-air operation. A systematic increase in bubble size down the bank was found. Cumulative bubble surface area flux down the bank showed no major differences between surveys. However, grade-recovery curves revealed that the highest recoveries were invariably obtained with forced air operation. Plotting concentrate mass recovery vs. enrichment ratio showed that the line performance could be controlled over a wider range when forced air was used.
Citation
APA: (2007) Forcing Air into Self-Aspirating Flotation Machines
MLA: Forcing Air into Self-Aspirating Flotation Machines. Canadian Institute of Mining, Metallurgy and Petroleum, 2007.