Abstract
(XP) enclosures to enclose electrical ignition sources to
prevent propagation of an internal methane-air explosion
to a surrounding explosive atmosphere. Researchers at the
National Institute for Occupational Safety and Health
(NIOSH) conducted a lithium-ion battery thermal runaway
test within a modified MSHA-approved XP enclosure
to assess thermal runaway containment. Thermal runaway
produced jet flames emanating from the cover joint at several
locations and distorted the cover joint and bottom
plate of the enclosure beyond allowable limits. The test
demonstrates that XP enclosures may not provide adequate
explosion protection against lithium-ion battery thermal
runaway. This paper suggests some approaches to mitigate
the hazard.