Abstract

(XP) enclosures to enclose electrical ignition sources to prevent propagation of an internal methane-air explosion to a surrounding explosive atmosphere. Researchers at the National Institute for Occupational Safety and Health (NIOSH) conducted a lithium-ion battery thermal runaway test within a modified MSHA-approved XP enclosure to assess thermal runaway containment. Thermal runaway produced jet flames emanating from the cover joint at several locations and distorted the cover joint and bottom plate of the enclosure beyond allowable limits. The test demonstrates that XP enclosures may not provide adequate explosion protection against lithium-ion battery thermal runaway. This paper suggests some approaches to mitigate the hazard.