Abstract
The validity and accuracy of velocity measurements underground have been questioned repeatedly by those in mine ventilation work. The general disagreement on the subject is well illustrated in an AIME publication.' Although the presence of errors is readily admitted, their magnitudes are not known and often are described by practical operators merely as "great," "small," or "of no importance." The belief that errors are of academic interest only prevails because of a justifiable claim that actual volumes of air circulated are well in excess of those required by law and safe mining practices. Poor understanding of the source and nature of errors inherent in velocity measurements, coupled with questionable determination of cross-sectional area, result in faulty techniques for the purpose of expediting ventilation surveys and render doubtful the calculated volume. Often consistency of readings is confused with accuracy. A succession of check readings showing a maximum deviation of 5 pct in the measured value of velocity usually signifies nothing more than diligent application of technique in a stable ventilating current.