DYNA Force-An Elasto-Magnetic Sensor For Force Measuring Of Post Tensioning Ground Anchors

- Organization:
- Deep Foundations Institute
- Pages:
- 8
- File Size:
- 4198 KB
- Publication Date:
- Jan 1, 2009
Abstract
On many occasions during construction and service life of the structure, it is crucial to know the load in post tensioning tendons and anchors. Although there are many methods to measure the tendon force, most of them are cumbersome, expensive and the accuracy differs depending on the method used Dyna Force sensor uses the Elasto-magnetic technology (EM) and non destructive testing (NDT) to direct measure stress level in prestressed strands or bars installed on ground anchors or post tensioning tendons. Dyna Force sensor can be used to rapidly read the change in load during proof and performance tests and compare with the pressure gauge and during the life on the anchor to monitor existing lock-off load. It can be used also to determine the load along the bonded length of the anchor allowing the contractor to increase or decrease this length. The paper presents Dyna Force operating principle and some applications. In conclusion, the Elasto magnetic technology applied through Dyna Force is a new and easy to use approach to monitor anchor load during proof test and service life of the structure.
Citation
APA:
(2009) DYNA Force-An Elasto-Magnetic Sensor For Force Measuring Of Post Tensioning Ground AnchorsMLA: DYNA Force-An Elasto-Magnetic Sensor For Force Measuring Of Post Tensioning Ground Anchors. Deep Foundations Institute, 2009.