Abstract
Quality control interventions emanate from process upsets and trends that move product quality
beyond the natural variation expected in a stable process. The ability to detect upset conditions and
react in an effective manner protects both resource utilisation and compliance to specifications.
Product quality control on coal processing plants traditionally relies on the reference (combined
sampler and laboratory) system to measure product qualities. The introduction of online analyser (OA)
technology, applied in different configurations, creates a second source of measurement information for
control decision making.
The case study was done on the primary sample stream of the final product stream at Exxaro’s
GG7 and 8 plants, part of the Grootegeluk complex. It explores the OLA system’s ability to meet the
OEM performance guarantee, perform equally to the reference system without analytical delay time,
and assesses the effort to achieve this performance in a by-line analyser (BLA) configuration.
In the paper, a conceptual comparison of the two measurement systems is done and the theoretical
and practical comparison of measurement performance is discussed. Results demonstrate that the OA
outperformed the OEM’s performance guarantee and achieved similar levels of performance to the
reference system without the response delay.
Keywords: Online analyser (OLA), by-line analyser (BLA), coal quality measurement, measurement
performance
Citation
APA:
(2020) Determining the expected and actual measurement performance of a by-line element analyser on a final product stream at Exxaro’s Grootegeluk 7 & 8 plants, H.N. Engelbrecht and M.V RoperMLA: Determining the expected and actual measurement performance of a by-line element analyser on a final product stream at Exxaro’s Grootegeluk 7 & 8 plants, H.N. Engelbrecht and M.V Roper. The Southern African Institute of Mining and Metallurgy, 2020.