Detection Of Water Leaks Using Efsop Water Detection Techonology®

- Organization:
- Associacao Brasileira de Metalurgia, Materiais e Mineracao
- Pages:
- 10
- File Size:
- 1196 KB
- Publication Date:
- Aug 16, 2017
Abstract
Tenova Goodfellow Inc. has successfully installed the proprietary EFSOP® (Expert Furnace System Optimization Process) system in over 80 installations worldwide. For over 15 years, the EFSOP® System has successfully achieved its main objective of improving performance and operating costs through the reduction of electricity, oxygen, methane, injected and charge carbon use. Using the off-gas information provided by the EFSOP® System, Tenova Goodfellow Inc. has now developed a solution for detecting abnormal water events within the EAF steelmaking process. When water form enters the EAF, it immediately forms into water vapor (H2Ogas) and a proportion of the resulting water vapour will further react and dissociate to H2. Effective water detection technology must be capable of detecting BOTH forms of water; H2Ogas & H2. Tenova Goodfellow has the technology to measure in real time and simultaneously H2Ogas & H2. This paper will provide a summary on how the EFSOP Water Detection Technology® is used during the EAF operation. Details regarding the technology, software, alarm rate and information on sensibility water trial tests will be provided within this paper.
Citation
APA: