Combined Loading Tests On Large Diameter Piles

Deep Foundations Institute
A. Lyndon
Organization:
Deep Foundations Institute
Pages:
5
File Size:
282 KB
Publication Date:
Jan 1, 1989

Abstract

Combined loading tests are described to three 1.2m diameter cast-in-place bored piles, 12m long, formed through cohesionless material into stiff sandy clay. The maximum loading conditions imposed at the pile head were 2400 kN vertical, 160 kN lateral and 3120 kNm in bending, corresponding to twice the working load. Settlements, deflections and rotations of the piles were measured during the tests. An interesting finding which the test results suggest is that, in the short term, vertical movement had apparently no marked effect on lateral performance for piles working at design loadings.
Citation

APA: A. Lyndon  (1989)  Combined Loading Tests On Large Diameter Piles

MLA: A. Lyndon Combined Loading Tests On Large Diameter Piles. Deep Foundations Institute, 1989.