Causes of Massive Directional Roof Falls in Room and Pillar Mines - Two Case Studies

International Conference on Ground Control in Mining
S. S. Peng
Organization:
International Conference on Ground Control in Mining
Pages:
10
File Size:
2472 KB
Publication Date:
Jan 1, 1999

Abstract

In recent years many roof falls have been conveniently attributed to the adverse existence of a high horizontal stress. The normal practice of not conducting a follow-up study in a roof fall investigation usually leads to a wrong conclusion. This paper describes two cases of massive oriented roof falls in two separate room and pillar mines. The investigation in each case involved the analysis of past history and current conditions from which remedial measures were recommended and implemented. A follow-up period of up to three years was performed to evaluate the effectiveness of the recommended remedial measures. In both cases, high horizontal stress was proven positively not the cause, contrary to the original conviction of mine management Rather, a weak immediate roof was the basic cause Under a weak immediate roof, a proper roof bolting plan and adequate entry width and intersection span must be strictly observed.
Citation

APA: S. S. Peng  (1999)  Causes of Massive Directional Roof Falls in Room and Pillar Mines - Two Case Studies

MLA: S. S. Peng Causes of Massive Directional Roof Falls in Room and Pillar Mines - Two Case Studies. International Conference on Ground Control in Mining, 1999.