Automation To Control Silica Dust During The Pallet Loading Process

Society for Mining, Metallurgy & Exploration
A. B. Cecala A. Covelli
Organization:
Society for Mining, Metallurgy & Exploration
Pages:
4
File Size:
355 KB
Publication Date:
Jan 1, 1992

Abstract

Two recent US Bureau of Mines studies evaluated workers' dust exposures in automated pallet loading processes. The first study involved a Bureau designed dust control system using a push-pull ventilation technique. The unit was shown to reduce workers' dust exposures by 76% during pallet loading at a ground silica operation. A hydraulic lift table was used to automate the bag stacking process. This kept the loading height constant throughout the entire pallet loading cycle. The second study evaluated different commercial, automated-pallet loading systems. These systems automatically stack the bags onto pallets, shrink wrap the pallets, and deliver the pallets to a fork lift pickup location. Results from a ground silica evaluation site indicated respirable dust samples taken were below the Threshold Limit Value (TLV) as established by the Mine Safety and Health Administration (MSHA).