Reverse performance characteristics of main fans in an oil shale mine

Rajaram, V. ; Thimons, E. D.
Organization: Society for Mining, Metallurgy & Exploration
Pages: 4
Publication Date: Jan 1, 1987
A mine fire or roof collapse may necessitate the reversal of main fans to isolate the fire or provide an escapeway. Hence, to assist the mine operator in estimating the flow and pressure during reversal, Engineers International Inc. conducted a laboratory and field study of the reverse performance characteristics of main mine fans. Laboratory tests were performed using a 2.4-m (96-in.) diam vane axial fan to establish the forward and reverse performance characteristics under controlled conditions. Subse¬quently, a field test was conducted in a Colorado oil shale mine during which two 2-m (79-in.) diam fans were reversed. The data obtained indicate that reverse performance characteristics depend on the blade angle and the hub-to-tip ratio. The quantity in the reverse mode ranged from 30% to 65% less than in the forward mode, and the static pressure was directly proportional to the square of the quantity.